TRT 01 Rail-Less Solar Mounting System for Asphalt Shingle Roofs

TRT01 Rail-Less Solar Mounting is built specifically for asphalt composition shingle roofs. It integrates the base and mini-rail into a single unit, attaches with double butyl adhesive, and requires no traditional flashing. The result is a faster installation with fewer components, a cleaner roof finish, and a fully waterproofed penetration that meets UL 2703 listing requirements.

The system is PE certified, Class A/B fire rated, and tested to ASTM D7147 and TAS 100(A) for uplift, shear load, and water penetration. For base spacing and layout requirements, use TRT’s PE-certified span tables.

For installers who need a repeatable, code-compliant workflow on composition shingle roofs, the TRT01 Rail-Less Solar Mounting system removes the alignment challenges that come with traditional rail-based systems. Fewer parts, simpler crew training, and the same consistent process across every attachment point on the roof.

Technical Overview

Product Specifications

Specification Detail
System TRT01 Rail-Less Base System
Roof Type Asphalt composition shingle
Certification UL 2703 Listed
Fire Rating Class A Class B
Testing ASTM D7147  •  TAS 100(A)
Frame Compatibility 30–40mm solar panel frames
Max Panel Size Less than 2278mm × 1134mm
Mid Clamp Frame Height 26–37mm
Skirt Clamp Frame Height 26–40mm
Material Aluminum 6005-T5, black anodized finish
Sealing Double butyl adhesive  •  No silicone
PE Certified ✓ Yes
Warranty 25 Years

01

UL 2703 LISTED

The entire system is fully compliant with UL2703 standards.

02

ASTM D7147 and TAS 100(A)

The base passed Florida high-wind, water-penetration, uplift, and shear-load testing

03

Class A/B fire rating

Certified to maintain the fire resistance rating of the existing roof.

04

PE certified

Reviewed and approved by a Professional Engineer (PE) to ensure compliance with safety standards and adequate load capacity.

05

25 years warranty

Ensures a worry-free experience throughout the product's service life.

06

Florida (HVHZ)

Approved FL47736

Need Answers?

Frequently Asked Questions

Does TRT01 require flashing on asphalt shingle roofs? +
No. TRT01 uses integrated double butyl adhesive sealing and does not require traditional flashing on composition shingle roofs. Building codes may reference flashing in general roof assembly contexts, but TRT01 does not rely on it as part of the system.
What sealant is compatible with TRT01? +
TRT01 uses butyl adhesive as the primary sealing method. Only butyl-compatible roofing sealants approved by the installation manual should be used where additional sealant is required. Silicone sealants and lubricants are not compatible with the butyl system and must never be used.
Is TRT01 approved for high wind zones including Florida? +
Yes. TRT01 has been tested to ASTM D7147 and TAS 100(A) standards for uplift, shear load, and water penetration, including Florida high-wind applications. Base spacing for specific wind and snow load conditions must follow TRT's PE-certified span tables.

Get A Quote